cf-execd

Table of Contents

cf-execd is the scheduling daemon for cf-agent. It runs cf-agent locally according to a schedule specified in policy code (executor control body). After a cf-agent run is completed, cf-execd gathers output from cf-agent, and may be configured to email the output to a specified address. It may also be configured to splay (randomize) the execution schedule to prevent synchronized cf-agent runs across a network.

cf-execd keeps the promises made in common bundles, and is affected by common and executor control bodies.

Note: This daemon reloads it's config when the SIGHUP signal is received.

History:

  • SIGHUP behavior added in 3.7.0

Command reference

  --help        , -h       - Print the help message
  --debug       , -d       - Enable debugging output
  --verbose     , -v       - Output verbose information about the behaviour of the agent
  --dry-run     , -n       - All talk and no action mode - make no changes, only inform of promises not kept
  --version     , -V       - Output the version of the software
  --file        , -f value - Specify an alternative input file than the default. This option is overridden by FILE if supplied as argument.
  --define      , -D value - Define a list of comma separated classes to be defined at the start of execution
  --negate      , -N value - Define a list of comma separated classes to be undefined at the start of execution
  --no-lock     , -K       - Ignore locking constraints during execution (ifelapsed/expireafter) if "too soon" to run
  --inform      , -I       - Print basic information about changes made to the system, i.e. promises repaired
  --diagnostic  , -x       - Activate internal diagnostics (developers only)
  --no-fork     , -F       - Run as a foreground processes (do not fork)
  --once        , -O       - Run once and then exit (implies no-fork)
  --no-winsrv   , -W       - Do not run as a service on windows - use this when running from a command shell (CFEngine Nova only)
  --ld-library-path, -L value - Set the internal value of LD_LIBRARY_PATH for child processes
  --color       , -C value - Enable colorized output. Possible values: 'always', 'auto', 'never'. If option is used, the default value is 'auto'
  --timestamp   , -l       - Log timestamps on each line of log output

Control Promises

These body settings determine the behavior of cf-execd,including scheduling times and output capture to WORKDIR/outputs and relay via email.

     body executor control
     {
         splaytime  => "5";
         mailto     => "cfengine@example.org";
         mailfrom   => "cfengine@$(host).example.org";
         smtpserver => "localhost";
         schedule   => { "Min00_05", "Min30_35" }
     }

agent_expireafter

Description: Maximum agent runtime (in minutes)

Sets a maximum time on any run of the command in exec_command. If no data is received from the pipe opened to the process created with exec_command after the time has elapsed, the process gets killed.

Note that if you have long-running jobs, they may get killed with this setting. Therefore, you should ensure it is higher than any run of cf-agent that you want to leave alone. Alternatively, you can make your jobs output something to STDOUT at least as often as this threshold. This will reset the timer.

Type: int

Allowed input range: 0,10080

Default value: 120

Example:

    body executor control
    {
    agent_expireafter => "120";
    }

Notes: The setting will effectively allow you to set a threshold on the number of simultaneous agents that are running. For example, if you set it to 120 and you are using a 5-minute agent schedule, a maximum of 120 / 5 = 24 agents should be enforced.

See Also: body action expireafter, body contain exec_timeout, body agent control expireafter

executorfacility

Description: Menu option for syslog facility level

Type: (menu option)

Allowed input range:

LOG_USER
LOG_DAEMON
LOG_LOCAL0
LOG_LOCAL1
LOG_LOCAL2
LOG_LOCAL3
LOG_LOCAL4
LOG_LOCAL5
LOG_LOCAL6
LOG_LOCAL7

See the syslog manual pages.

Default value: LOG_USER

Example:

    body executor control
    {
    executorfacility => "LOG_USER";
    }

exec_command

Description: The full path and command to the executable run by default (overriding builtin)

The command is run in a shell encapsulation so pipes and shell symbols may be used if desired.

Type: string

Allowed input range: "?(/.*)

Example:

exec_command => "$(sys.workdir)/bin/cf-agent -f failsafe.cf && $(sys.workdir)/bin/cf-agent";

mailfrom

Description: Email-address cfengine mail appears to come from

Type: string

Allowed input range: .*@.*

Example:

    body executor control
    {
        mailfrom => "mrcfengine@example.org";
    }

mailmaxlines

Description: Maximum number of lines of output to send by email

This limit prevents anomalously large outputs from clogging up a system administrator's mailbox. The output is truncated in the email report, but the complete original transcript is stored in WORKDIR/outputs/* where it can be viewed on demand. A reference to the appropriate file is given.

Type: int

Allowed input range: 0,1000

Default value: 30

Example:

    body executor control
    {
    mailmaxlines => "100";
    }

mailsubject

Description: The subject in the mail sent by CFEngine.

The subject can contain system variables, like for example IP address or architecture.

Type: string

Allowed input range: .*

Example:

    body executor control
    {
        mailsubject => "CFEngine report ($(sys.fqhost))";
    }

mailto

Description: Email-address cfengine mail is sent to

The address to whom email is sent if an smtp host is configured.

Type: string

Allowed input range: .*@.*

Example:

    body executor control
    {
        mailto => "cfengine_alias@example.org";
    }

schedule

Description: The class schedule used by cf-execd for activating cf-agent

The list should contain class expressions comprised of classes which are visible to the cf-execd daemon. In principle, any defined class expression will cause the daemon to wake up and schedule the execution of the cf-agent. In practice, the classes listed in the list are usually date- and time-based.

The actual execution of cf-agent may be delayed by splaytime, and may be deferred by promise caching and the value of ifelapsed. Note also that the effectiveness of the splayclass function may be affected by changing the schedule.

Type: slist

Allowed input range: (arbitrary string)

Default value:

schedule => { "Min00", "Min05", "Min10", "Min15", "Min20", "Min25",
          "Min30", "Min35", "Min40", "Min45", "Min50", "Min55" };

Example:

    body executor control
    {
    schedule => { "Min00", "(Evening|Night).Min15_20", "Min30", "(Evening|Night).Min45_50" };
    }

smtpserver

Description: Name or IP of a willing smtp server for sending email

This should point to a standard port 25 server without encryption. If you are running secured or encrypted email then you should run a mail relay on localhost and point this to localhost.

Type: string

Allowed input range: .*

Example:

  body executor control
  {
      smtpserver => "smtp.example.org";
  }

splaytime

Description: Time in minutes to splay this host based on its name hash

Whenever any class listed in the schedule attribute is present, cf-execd can schedule an execution of cf-agent. The actual execution will be delayed an integer number of seconds between 0-splaytime minutes. The specific amount of delay for "this" host is based on a hash of the hostname. Thus a collection of hosts will all execute at different times, and surges in network traffic can be avoided.

A general rule for scaling of small updates is to set the splay time to runinterval-1 minutes for up a few thousand hosts. For example, the default schedule executes once every 5 minutes, so the splay time should be set to no more than 4 minutes. The splaytime should be set to a value less than the cf-execd scheduling interval, else multiple clients might contend for data. In other words, splaytime + cf-agent run time should be less than the scheduling interval.

Type: int

Allowed input range: 0,99999999999

Default value: 0

The CFEngine default policy sets splaytime to 1.

Example:

  body executor control
  {
      splaytime => "2";
  }