CFEngine for Mission Critical Operations


Next: , Previous: (dir), Up: (dir)

CFEngine for Mission Critical Operations

COMPLETE TABLE OF CONTENTS

Summary of contents


Next: , Previous: Top, Up: Top

What are Mission Critical Operations?


Mission Critical operation refers to the use and management of systems where the availability and correctness of a system has to be ensured at all times. A mission is said to be critical when any noticable failure in the system would cause a signifiant loss to some stakeholder.

Risk for mission critical systems deals with issues like monetary losses (e.g. in time critical trading applications) or, in the worst case, even the loss of human life (transport systems).

What makes a system robust in a mission critical setting depends on a number of factors. This Special Topics Guide discusses the role of CFEngine in a mission critical environment.


Next: , Previous: What are Mission Critical Operations?, Up: Top

Factors affecting Risk


Risk is about predictability. The ability to predict the behaviour of a system depends both on the complexity of the system itself and the environment around it, since interaction with the environment is what usually provokes failures (the environment is the most unpredictable element of any system, since it is the part over which we have little control).

The cost of predicting and avoiding failures can be prohibitive in a purely manual regime but automated systems can do a lot to reduce costs. CFEngine can play a key role here in reducing the cost of maintaining system state, even in a rapidly changing environment.



The key observation for dealing with mission criticality is that systems are dynamical entities. Most software systems only manage the static setup of hosts. CFEngine manages both the static resources and the run-time state.


Next: , Previous: Factors affecting Risk, Up: Top

Model-based planning for stability


The key to handling mission criticality is to build a model of your critical scenario that is based on a prediction of behaviour. In science and engineering, this is something one does all the time (e.g. wind-tunnel studies), but in Computer Engineering, the methods of modelling are still quite undeveloped. In the nuclear power industry and space programmes, for instance, it is common to use formalized fault-analysis to avoid and secure against error.

The purpose of a model is to describe expectations. If a model is sufficiently well conceived, it should be possible to identify key causal factors in the mission that bring about critical behaviour.


CFEngine's methodology is based on the idea of promises: a promise being something that aims to alter our expectations of outcome in a postive way.


In CFEngine, you make promises about the factors that underpin the stability of your system, and CFEngine's task is to work on your behalf to keep those promises. Promises cannot be guaranteed `kept' at all times, especially in time-critical situations (such a guarantee would require infinite resources to maintain), but a known schedule of verification and repair allows us to bring a level of predictability to a system, within certain tolerances. This is a best-effort engineering definition of predictability.

Examples of promises that you might want to include in a foundation for a mission critical system are things that bring trusted stability, e.g.

The economic aspect of mission criticality is key: the loss of a key application or subsystem for even a minute could result in loss of significant revenues in an online company, or the loss of flight systems for a few seconds could result in a plane losing control and crashing.


Next: , Previous: Model-based planning for stability, Up: Top

Key terminology for Mission Critical Systems


Mean Time Before Failure (MTBF)
The average measured time between faults occurring on a system. Although this is a well established measurement in the theory of faults and errors, estimating this quantity is not without its challenges.
Mean Time To Repair (MTTR)
The average time it takes to repair a system after a failure has occurred. The type or meaning of repairs is not specified.
Sampling frequency
The rate at which we interact with the system in order to measure or repair it. According to Nyquist's theorem, we have to sample a system twice as fast as the rate at which we expect to detect an important change.
Single point of failure
Any point in the design of a system that would lead to complete failure if destroyed. There might be several `single points of failure' in a system. Single refers to the fact that it only takes the failure of one of these to cause the total breakdown of the system. For example, the axel, or a tyre on a car would be examples of single points of failure for the `driving system'.


Next: , Previous: Key terminology for Mission Critical Systems, Up: Top

Strategy for Mission Critical Operations


There are many aspects to thinking about complete reliability of systems.

The main goal of any system is to seek predictability. Having clear and accurate expectations of a system helps to steer it in a low-risk direction.

Usually these fall into a mixture of two categories:

Redundancy
Elimination of `single points of failure' when failure strikes.
Avoidance
Proactive maintainence to keep the system in a zone of low risk.
Certainty of knowledge
Knowing accurately what is going in a system can enable correct decisions to be made more quickly when something unexpected happens.

It is impossible to discuss a comprehensive list of points for ensuring reliability, but a few general principles come to mind:


Next: , Previous: Strategy for Mission Critical Operations, Up: Top

How CFEngine contributes to reducing mission risks



Next: , Previous: How CFEngine contributes to reducing mission risks, Up: Top

High availability access to the Mission Portal


CFEngine is designed to be a system that is resilient to failure. That, in fact, is the opposite of a high availability system, where failures are not supposed to occur at all.

The Mission Portal has a role to play in Mission Criticality, as it is a single source of information, collected, categorized and calibrated for system engineers. Being a single source website, it is can also be regarded as a single point of failure from the point of view of a mission critical application.

The information in the mission portal is largely status information about systems. The content of the Mission Portal database is not in any way deterministic for the configured state of your IT system – it is only a report of actual state, not a template for intended state. If the Mission Portal is `down' or unavailable, it does not in any way imply that the actual distributed system is down or that there is any fault.


Previous: High availability access to the Mission Portal, Up: High availability access to the Mission Portal

Setting up redundant monitoring hubs

If information and insight into your IT system are indeed Mission Critical for you, it is possible to create a high availability access to the mission information in the portal. In general, we recommend a small amount of professional services to help set up such a system, as there are several details that need to be taken into account.

The CFEngine star-network `hub' is the report aggregator for the CFEngine commercial edition (Nova/Enterprise). CFEngine commercial editions support multiple hubs for redundancy during reporting. By making a cluster of three (or more) hubs, you can ensure that reports will always be available and up to date, at the time-resolution promised by CFEngine.

To set up redundant hubs, you will need three physical computers, or at least three virtual machines on different physical computers. The idea is to use the underlying technology of the MongoDB database to provide a replicated data store. If a single database server goes down a secondary replica can take over the role. The commercial editions of CFEngine interface with this database through cf-hub, and this process can be made aware of the underlying replica technology in the database. The architecture is intended to be as simple as possible for the CFEngine user to employ.



Next, we'll run through the operation and failure modes of the symmetric hubs. The arrangement of the hubs is shown schematically in the figure below.

redundhubs.png

Fig 1. Only one master hub at a time collects data in a symmetric cluster.


Next: , Previous: High availability access to the Mission Portal, Up: Top

Redundant hub architecture

To set up redundancy, you create three hubs, each running a Mongo database server and a cf-hub process will play the role of a virtual cluster. All three hosts make promises to one another to coordinate their data. The Mongo replica sub-system promises its own coordination independently. We essentially make three completely symmetrical hub hosts, with different IP addresses.

  1. Set up three completely symmetrical hosts, with identical public-private key pairs. That is, generate a key pair only for one of the hubs and then copy those keys to /var/cfengine/ppkeys/localhost.pub and /var/cfengine/ppkeys/localhost.priv on the other two hosts. This must be done manually to bootstrap the hub redundancy.
  2. The underlying Mongo database infrastructure binds together these hosts into a small cluster called a replica set.

    A voting mechanism selects a `hub_master' from this set, which is going to be the active hub.

  3. Each host is configured to copy the public keys from all the others, so that they all converge on the same set of keys. The following snippet shows the main principles involved in a replica setup.
         vars:
         
           "hub_hosts" slist => { "hub1", "hub2", "hub3" };
         
         files:
         
          am_policy_hub::
         
            "$(sys.workdir)/ppkeys"
                comment => "All hubs converge knowledge of client keys",
              copy_from => secure_cp("$(sys.workdir)/ppkeys","$(hub_hosts)"),
           depth_search => recurse("inf");
         
    
  4. For optimization we set up a policy that rewrites the IP address in policy_server.dat, to point existing clients away from a hub that is no longer responding, to the current master or primary. Clients will initially pick up these changes by failing over, as in the previous point.
         files:
         
          am_hub_master::
         
            "$(sys.workdir)/policy_server.dat"
                 comment => "Point clients to the current hub master",
               edit_line => append_if_no_line("$(sys.hub_master)")
           edit_defaults => empty;
         
    
  5. To make the redundany hubs double as redundant policy servers, we make sure that the copying of policy in update.cf uses the replicas as failover servers for policy updates. This means that changes to policy should always be copied to /var/cfengine/masterfiles on all three hub hosts.
         body copy_from update_copy
         {
         ...
         servers => { $(sys.policy_server), "hub3", "hub2", "hub1" };
         ...
         }
    
    The policy server variable will point to one of these hubs. If a hub host, doubling in its role as policy server, fails for some reason, the clients will all fail over to the next hub, and updates will continue. By the time this happens, we can expect the main policy will have been adjusted by the edit in the previous point, and clients will be pointed to a new primary. It does not matter that hosts appear twice in the list; we could, for instance place hub1 last in the list if we assume that hub1 is the initial primary, so as to minimize the wait due to a double-failover.

With this configuration, all the hubs promise to synchronize their keys, and share `last seen' client host data with each other in order to symmetrize. However, only one of the hubs actually collected reports from the clients. This is the host that is elected by the MongoDB replica-set vote.


With the approach taken above we can be sure that data are being collected redundantly without duplication of network overhead.

Note that the standard Nova configuration files contains example configurations for the replica set configuration. Integrating all the settings can require extensive modifications, as mentioned above.


Next: , Previous: Redundant hub architecture, Up: Redundant hub architecture

Features of hub/policy server redundancy

The Nova starburst hub configuration supports the following properties:


Previous: Features of hub/policy server redundancy, Up: Redundant hub architecture

Variables and classes for hubs

CFEngine Nova/Enterprise supports special classes to help write policy for managing the hub infrastructure.

am_policy_hub
am_hub_master

The variable ‘$(sys.hubmaster)’ is also available on hosts that are hubs, and points to that host currently voted into the role of hub master.


Setting up redundant hubs might be best done with some professional service assistance. Although it is quite simple, it changes the bootstrapping procedure in the beginning of a Nova/Enterprise deployment.


Next: , Previous: Redundant hub architecture, Up: Top

How do I make a change in mission-critical infrastructure?


To make changes in a mission critical environment, you publish a fully tested, risk-assessed policy to /var/cfengine/masterfiles on all three of the hubs in the cluster. The policy on all hubs should be the synchronized. It might be worth setting up a promise to verify that the contents of these directories are the same between all hubs, since unsychronized policies could cause serious issues.
vars:

   "hubs" slist => { "hub1", "hub2", "hub3" };

files:

  "$(sys.workdir)/masterfiles"

    copy_from => secure_cp("$(sys.workdir)/masterfiles","$(hubs)"),
       action => warn;

All changes to a mission critical system should be classified according to the level of risk to the mission. Changes fall into different categories.

In each case, we recommend that changes be made using CFEngine's hands-free automation. Humans should never be the instruments of change. By using CFEngine, you can get a documented and predictable handle on change, using technology designed for stability with agility.

CFEngine has the ability to change entire systems of thousands of hosts within a timeframe of 5 to 10 minutes.


Next: , Previous: How do I make a change in mission-critical infrastructure?, Up: Top

Separating Policy Changes from ad-hoc Changes


In mission critical environments, there are often struct processes for approving change. Unintelligently applied, such rules can do more harm than good – i.e. when the process for approving changes causes greater risk to the survival of the mission than not acting at all does. It is important to separate changes into categories that allow the minimization of risk. If we take the categories in the previous section:
Regular routine maintenance to the system (preplanned).
Changes here have alredy gone through risk assessment, and root cause has been deemed understood or irrelevant. These changes should be automated and implemented in the minimum time. e.g. restarting a web server that crashed or was stopped accidentally.
Course or goal corrections to policy (replanned).
This is a change in the mission plan and requires significant impact analysis for each change. Although many businesses are concerned about liabilities, the real aim of this analysis is to mitigate loss.
Unforeseen repairs (unplanned).
These changes are usually discovered and repaired manually. Once some kind of root cause analysis is performed to the required level, there should be an analysis of how to automate the prevention of this kind of change in the future.


This is a partially finished Special Topics Guide, in which additional material can be expected at a later date. It is made available in its current form for your convenience.


Next: , Previous: Separating Policy Changes from ad-hoc Changes, Up: Top

Appendix MongoDB access from the command line.

Using more than one hub at a time: If you want to be able to perform queries on any one of the redundant hosts, not only the master, then it's necessary to set a flag on each of the running mongo servers (master and slave):
host$ mongo

rs.slaveOk();
This ensures that updates are synchonrized for querying. e.g. In this example we see the first query fail, and the second succeed after setting the flag:
CFEngineNova:SECONDARY> use cfreport
switched to db cfreport

CFEngineNova:SECONDARY> db.notebook.find();
error: { "$err" : "not master and slaveok=false", "code" : 13435 }

CFEngineNova:SECONDARY> db.notebook.find();
CFEngineNova:SECONDARY> rs.slaveOk();     
not master and slaveok=false
CFEngineNova:SECONDARY> db.notebook.find();
{ "_id" : ObjectId("4e5cd788d5d6b92c00000000"), 
"_kh" : "SHA=9e9ad21d192fa...1635", 
"_rD" : "0 : 10.10.160.115", "_t" : 1, "n" : [
    {
        "u" : "admin",
        "m" : "This machine is a web server",
        "d" : 319944880
    }
] }


Previous: Appendix 1, Up: Top

Appendix Shutting down Mongo with replication

Anytime you shutdown mongo, it will automatically failover. You can~t specifically tell which node to become primary, but you can use replFreeze and replSetStepDown to alter which is eligible to become primary (small difference).

Basically we would freeze a node from becoming primary, then tell the primary to step down, which leaves only one node (see http://www.mongodb.org/display/DOCS/Forcing+a+Member+to+be+Primary for a good explanation).

However, failover is the easy part. The other half to the action is that all client will receive a new policy_server.dat based on the new primary. This will create quite a flux in the system for a bit as it reconfigure. This will take 10-20 minutes for everyone to stabilize. I would reserve a full failover for when the primary will be down for an extended period of time.

Since the outages you have are fairly quick, I would just shutdown mongo/cfengine (or freeze) the secondaries to prevent a failover. Shutting them down would prevent all client from getting new files, but that shouldn~t be an issue.

If you freeze the secondaries, and leave CFE runnning, the clients will update from the secondaries (they will get a license error).

To freeze the secondaries:

On any node:

# mongo -host `IP OF THE SECONDARY' # or login to the node and run plain ´mongo¡.
> rs.status()                       # this will show the status of the replicaSet
> rs.freeze(seconds)                # how many seconds before the host can become primary.
> exit

Set the freeze for several hours (for four hours - ‘rs.freeze(14400)’). Then shutdown cfengine on the primary as normal (/etc/init.d/cfengine3 stop). When you are done with the change, bring up cfengine (cf-agent -f failsafe.cf), then set the freeze time for 0 seconds to unfreeze it (‘rs.freeze(0)’).